Huber Unichiller P022 with Pilot ONE
Features
- Environmentally-friendly, economic cooling solution
- High efficiency
- Precise temperature control
- Powerful circulation pump
- Robust stainless construction
- Reliable continuously operation with warning functions
- Easy to fill and empty
- Adjustable bypass, level indicator with sight glass and digital manometer
- Pilot ONE controller with 5.7" touchscreen
- 2 x USB (Host and Device), Ethernet and RS232 interfaces
| General information & temperature controller | |
|---|---|
| Temperature range | -10...40 °C |
| Temperature stability | ±0.5 °C |
| Temperature Control | TAC, self-optimizing (True Adaptive Control) |
| Display resolution | 0.01 °C |
| Alarm message | optical, acoustical |
| Controller | Pilot ONE (E-grade "Professional") |
| Safety class | I / NFL |
| Protection class | IP20 |
| Dimensions (W x D x H) | 18.11 x 23.23 x 29.25 inches |
| Weight | 176.4 pounds |
| Heating / cooling capacity | |
| Cooling capacity | 15 0 -10 C 2,2 1,6 1 kW |
| Cooling machine | air-cooled |
| Refrigerant (ASHRAE, GHS) | R507 (A1, H280) (0,64 kg) |
| Circulation pump | |
| Pressure pump max. | 25 lmp ; 2.5 bar / 6.6 gpm ; 36.25 psi |
| Pump connection | G3/4 AG male |
| Connections | |
| Pt100 connection | Pt100 |
| Digital interface | RS232, Ethernet, USB Device, USB Host |
| Operating data | |
| Permissible ambient temp. | 5...40 °C |
| Filling volume min. | 3.8 Liters / 1 gal |
| Volume of expansion | 1.7 Liters / 0.45 gal |
| Power supply | 208V 2~ 60Hz |
| Current max. | 10 A |
Miscellaneous
Please take further technical information as well as information about the scope of delivery, accessories and peripheral devices from the . In cases of doubt the details given in there apply. If nothing to the contrary is quoted then the performance data referred is at an ambient temperature of 20°C.
Please observe the and/or the space requirements of our products. The following voltage and frequency tolerances apply based on EN60034-1: Voltage +/- 5% for a frequency tolerance at the same time of +/- 2%.
Examples to illustrate this: Not permissible, for example. is -5% on the voltage and +2% on the frequency. Permissible, on the other hand, are tolerances of -5% on the voltage and -2% on the frequency.
This equipment is compliant to US-SNAP and all applicable EU laws. The US-SNAP end-use for this equipment is the industrial process refrigeration. Certification by a Notified Body upon request.
We reserve the right to make technical changes and correct errors. Illustrations can deviate from the original.
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.





