Across International Binder CB-S 260 C02 Incubator

Save $248.04 USD
Power Lab Supply 2SKU: Binder260

Price:
Sale price$12,153.96 USD Regular price$12,402.00 USD
Description

Model CB-S 260 / CO2 incubators with hot air sterilization

The durable and affordable CB-S series incubators are suitable for routine cell cultivation applications in the field of cell production, particularly in academic settings. They are contamination-proof due to 180 °C hot air sterilization and reliably pH-stable thanks to the drift-free infrared CO2 measurements conducted in real-time.

 

Benefits

• Safe – cell cultures receive maximum protection against contamination
• Reliable – constant well-being conditions for the cells
• Smart – simple routine cleaning and convenient operation
• Economical – efficient operation without consumables

 

Main Features

• Temperature range: +6 °C above ambient temperature to +50 °C
• Humidity range: 90 to 95% RH
• CO2 control range: 0 to 20 vol.% CO2
• Tried-and-tested anti-contamination concept with 180 °C hot air sterilization
• Humidi cation system with condensation protection
• CO2 gas mixing jet with Venturi efect
• CO2 sensor with infrared technology
• LCD to display temperature and CO2 along with additional information and alarms
• Internal data logger, measured values can be read out in open format via USB
• Tightly fitted inner door made of safety glass
• Seamless stainless steel inner chamber
• Perforated shelves, stainless steel
• Troubleshooting system with visual and acoustic alarms
• Interfaces: Ethernet, USB, zero-voltage alarm contact
• Units can be stacked with stacking adapters; the CB-S is suitable for stacking with CB and CBF models of the same size
 
Optional Equipment
• Copper interior fitings consisting of copper shelves and copper-plated water pan
• Stacking adapter for secure, space-saving installation
• CO2 gas tank changer for connecting two gas tanks to one or two incubators
• CO2 shaker with corrosion-resistant components in a stainless-steel housing
• APT-COM Multi Management Software – for managing, recording, and documenting unit parameters
• Services – wide range of services to ensure that the unit functions correctly
 





 

 

 

 

 

 

 

 

 

 

 

 

Specifications
SPECIFICATIONS

 

Model Model CB-S 260
Voltage 120 V 1~ 60 Hz
230 V 1~ 50/60 Hz
Recovery time after 30 seconds door open at 37 °C [min] 8
Temperature fluctuation at 37 °C [± K] 0.1
Temperature range +6 °C above ambient temperature to 50°C
Humidity range 90-95
Temperature variation at 37 °C [± K] 0.4
Number of shelves (std./max.) 2/8
Housing dimensions not incl. fittings and connections W x H x D [in]
30.93 x 40.2 x 29.16
Internal dimension W x H x D [in] 22.65 x 29.55 x 24.43
Net Weight Ibs 269
Interior Volume cu.ft. 9.4

 

All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.

Specifications
SPECIFICATIONS

 

Model Model CB-S 260
Voltage 120 V 1~ 60 Hz
230 V 1~ 50/60 Hz
Recovery time after 30 seconds door open at 37 °C [min] 8
Temperature fluctuation at 37 °C [± K] 0.1
Temperature range +6 °C above ambient temperature to 50°C
Humidity range 90-95
Temperature variation at 37 °C [± K] 0.4
Number of shelves (std./max.) 2/8
Housing dimensions not incl. fittings and connections W x H x D [in]
30.93 x 40.2 x 29.16
Internal dimension W x H x D [in] 22.65 x 29.55 x 24.43
Net Weight Ibs 269
Interior Volume cu.ft. 9.4

 

All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.

Payment & Security

American Express Apple Pay Diners Club Discover Meta Pay Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.