{"product_id":"edwards-e2m275-rotary-vane-dual-stage-mechanical-vacuum-pump","title":"Edwards E2M275 Rotary Vane Dual Stage Mechanical Vacuum Pump","description":"\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eEdwards E2M275 Rotary Vane Dual Stage Mechanical Vacuum Pump PFPE Prepared\u003cbr\u003e200\/380-440 50Hz, 208-230\/440-480V 60Hz, PFPE Prepared, IE3 EU\/US Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese Edwards E2M275 direct drive PFPE rotary vane pumps are inherently compact and vibration free with an ultimate pressure of 7.7x10-4 Torr and a pumping speed of 206 CFM at 60 Hz. These Edwards E2M275 vacuum pumps offer a finger-proof coupling housing and totally enclosed fan-cooled motors, which provide excellent operator protection. The Edwards E2M275's give the best combination of performance, reliability, and cost in their class.\u003cbr\u003e\u003cbr\u003eThe Edwards E2M275 dual stage rotary vane mechanical vacuum pumps have an advanced oil lubrication circuit and are very reliable with accessories to match any application. Applications include use with refrigeration dehydration, brake line evacuation, thin film coating, vacuum distillation, freeze drying, space simulation and other chemical processes. These brand new Edwards E2M275 dual stage PFPE rotary vane pumps come with an Edwards manufacturer's warranty. Oil and accessories are also available. Part number A36717940\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"font-size: 19px;\"\u003eOil Rotary Vane Pumps Two-Stage\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eRotary vane pumps are considered wet, positive displacement pumps, with the term “wet” denoting that the gases being pumped are exposed to oil. The significant characteristic of oil sealed rotary vane (OSRV) pumps is the use of oil as a sealant and coolant.\u003c\/p\u003e\n\u003cp\u003eTwo-stage rotary vane vacuum pumps use a two stage compression offering high pumping speeds combined with low ultimate pressure. They are widely used in industrial, chemical, pharmaceutical, and food industries.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"font-size: 19px;\"\u003eE2M Two Stage RVP\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eEM series pumps are rugged mechanical oil-sealed pumps with speeds ranging from 0.7 to 275 m3\/hr (30 to 206 CFM). Compact and quiet, they feature advanced lubrication circuits, high reliability, and accessories to suit specific application needs.\u003c\/p\u003e\n\u003cp\u003eEM products serve two major application sectors.\u003c\/p\u003e\n\u003cp\u003eIn scientific and laboratory applications, the E2M0.7-2.5 and E2M18\/28 are the ideal partners for your turbomolecular pump.\u003c\/p\u003e\n\u003cp\u003eIn Industrial applications, E2M18\/28, E2M40\/80 and E2M175\/275 offer very robust solutions in demanding applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for reliable and long term operations in both labs and Industrialenviornment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-teams=\"true\"\u003eEdwards product code: A36704940\u003cbr\u003e\u003cstrong\u003eWater-cooling required\u003c\/strong\u003e\u003cbr\u003eYour pump is water cooled. We recommend that you use a thermostatic controlled valve to regulate water flow. This will ensure optimum pump working temperature, maintain economies in water use, and provide assistance with gas‑ballast protection. The thermostatic control valve is an accessory, refer to Service, spares and accessories on page 43.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-teams=\"true\"\u003e\u003cbr\u003eRefer to Service, spares and accessories on page 43 for details about vibration isolators and other recommended accessories.\u003cbr\u003e\u003cbr\u003eConnect the pump to the cooling water \u003cbr\u003e\u003c\/span\u003e\u003cspan data-teams=\"true\"\u003eConnect the two 3\/8 in. BSPP\/T internally threaded connections to the cooling water supply. The maximum pressure that can be admitted to the cooling circuit is 3 bar and the recommended minimum cooling water supply flow rates at 20 °C are: E2M275 120 l h-1\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan data-teams=\"true\"\u003eYour pump will reach optimum operating temperature and will operate more efficiently if the temperature is controlled by the TCV300 thermostatic control valve.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e \u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%; border-width: 1px;\"\u003e\u003cstrong\u003e222.00 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.0511px;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%; border-width: 1px;\"\u003e\u003cstrong\u003e45.8 inch \/ 1165mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.0511px;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%; border-width: 1px;\"\u003e\u003cstrong\u003e20.98 inch \/ 533mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.0511px;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%; border-width: 1px;\"\u003e\u003cstrong\u003e15.28 inch \/ 388mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 60.1705px;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise \/ Sound Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%; border-width: 1px;\"\u003e\u003cstrong\u003e75.00 db(A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 79.2614px;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Inlet \/ Outlet Flange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%; border-width: 1px;\"\u003e\u003cstrong\u003eDN 63 ISO-F \/ DN 40 ISO-F\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 98.3523px;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension Comments\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%; border-width: 1px;\"\u003e\u003cstrong\u003eThe dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.0511px;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification Motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%; border-width: 1px;\"\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Total Rated @60Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e8.50 kW\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Total Rated @50Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e7.50 kW\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePumping Speed Air Nitrogen 60Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e180.10 Torr\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePumping Speed Air Nitrogen 50Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e150.09 Torr\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePressure Water Vapour Max\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e1.5 Torr\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eNominal Rotational Speed 50Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e25.00 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eCapacity Water Vapour\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e6.944 × 10⁻⁴ kg\/s\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eDisplacement @50Hz Max\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e171.86 cfm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePressure Ultimate With Gas Ballast\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e9.976 × 10⁻³ Torr\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePressure Ultimate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e2.475 × 10⁻³ Torr\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eNominal Rotational Speed 60Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e30.00 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eDisplacement @60Hz Max\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e206 cfm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eAltitude Max\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e1.000 × 10⁶ mm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eLubricant Capacity Min\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e0.019 m³\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eLubricant Capacity Max\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e0.028 m³\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Inlet Gas Max\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e70°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.0653px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003ePressure Absolute Outlet Continous Max\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e1125.09Torr\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Ambient Operation Max\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Ambient Operation Min\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e12°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Ambient Storage Min\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e-30°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Ambient Storage Max\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003e70°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.9886px;\"\u003e\n\u003ctd style=\"width: 37.6368%;\"\u003e\u003cstrong\u003e\u003cspan\u003eClassification Dry or Wet Pump\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 62.3536%;\"\u003e\u003cstrong\u003e\u003cspan\u003eWet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Power Lab Supply 2","offers":[{"title":"No thanks \/ I do not need liftgate service","offer_id":49645272137956,"sku":"E2M275","price":22513.1,"currency_code":"USD","in_stock":true},{"title":"No thanks \/ Yes I need liftgate service","offer_id":49645272170724,"sku":"E2M275121","price":22565.35,"currency_code":"USD","in_stock":true},{"title":"EH1200 Mechanical Booster Pump 3Ph 230\/460V 60Hz HC Oil A30506946 \/ I do not need liftgate service","offer_id":49645272203492,"sku":"E2M275211","price":54036.95,"currency_code":"USD","in_stock":true},{"title":"EH1200 Mechanical Booster Pump 3Ph 230\/460V 60Hz HC Oil A30506946 \/ Yes I need liftgate service","offer_id":49645272236260,"sku":"E2M275221","price":54089.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0658\/3130\/5444\/files\/edwards_used_e2m275b.jpg?v=1786637297","url":"https:\/\/powerlabsupply.com\/products\/edwards-e2m275-rotary-vane-dual-stage-mechanical-vacuum-pump","provider":"Power Lab Supply","version":"1.0","type":"link"}